How do you relight a RobertShaw water heater?

How do you relight a RobertShaw water heater?

Depress and hold gas control knob down completely and light the pilot. Continue to hold the gas control knob down for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back up. Pilot should remain lit.

How do you light a RobertShaw gas pilot?

Lighting a pilot light on RobertShaw and Rodgers-White gas control valves

  1. Set the thermostat to its lowest settings.
  2. Put the control knob to the OFF position.
  3. Wait for a few minutes to clear any gases.
  4. Turn the gas control knob to the “Pilot” position.
  5. Depress and hold down the pilot set button or gas control knob.

How do I turn on my electric pilot light?

How to Relight an Automatic Pilot Light

  1. Set the thermostat on your furnace to its lowest setting.
  2. Remove the access panel covering the gas control knob.
  3. Turn the gas control knob to the OFF position.
  4. Turn the gas control knob or knobs to the ON position.
  5. Turn the electrical power to the furnace back on.

Can you manually light a pilot light?

Lighting the Pilot Light on a Manual Hot Water Heater Turn the pilot dial to the off position and wait 5-10 minutes for any gas to dissipate. Then, turn the pilot dial until it says the word pilot. After that, set your temperate knob to low. Now, hold the pilot dial down while you light the burner.

What do I do if my pilot light won’t light?

Check the Thermocouple If your pilot light won’t stay alight, it might be the thermocouple. Sometimes dust buildup collects on the thermocouple and blocks the sensor. Try cleaning the thermocouple and then relighting the pilot light. If it continues to go out, the thermocouple might need to be replaced.

How do I know if my pilot light is out?

How to Tell If the Pilot Light Is Out

  1. Locate the front cover panel on your furnace. It should be a little door that’s easily visible.
  2. If your pilot light is on, it should be easy to see – your eyes will be drawn to the little flame.
  3. If you don’t see a flame, your pilot light is out.
  4. If there is a flame, check the color.

Is it dangerous if pilot light goes out on water heater?

Is it Dangerous if the Water Heater’s Pilot Light Goes Out? In most cases, it isn’t dangerous when the water heater pilot light is extinguished. This is because modern gas-fueled water heaters feature valves that automatically close the supply of gas when the pilot light goes out.

Does gas turn off when pilot goes out?

The pilot light provides a small flame that ignites the gas needed to operate the appliance. This is because all modern gas appliances with pilot lights have a fail-safe device that closes off the gas to the appliance in the case when the pilot may go out. The fail-safe device is comprised of a thermocouple.

Can a pilot light cause carbon monoxide?

A yellow or orange pilot light will produce carbon monoxide – an odourless, colourless gas that can fill your home and cause carbon monoxide poisoning. Symptoms of this condition include dizziness, headache, fatigue, nausea, unconsciousness, brain damage and death.

What color should my pilot light be?

blue

Should the flame touch the thermocouple?

The pilot flame should touch the thermocouple at a specific level. If the flame is blue and weak, and barely reaches the thermocouple, it needs to be stronger. If it extends well above the thermocouple, it’s too strong.

How do I know if thermocouple is bad?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

How much does it cost to replace a thermocouple?

The thermocouple is an apparatus that senses whether the pilot light is lit and triggers the gas control valve. Repairs typically cost about $150 to have it done professionally, though a new thermocouple itself only costs about $20 on average.

Can you bypass a thermocouple?

To bypass the thermocouple: Move the tilts switch wire aside. Remove your thermocouple from the heater using an 8mm wrench. Pull the valve housing aside using your 13mm socket wrench.

Can you fix a thermocouple?

If the pilot lights but the flame goes out as soon as you release the button after holding it for 60 seconds, then the thermocouple is bad. It’s possible to replace the thermocouple without removing the burner assembly, and many repair people do this.

Can I replace a thermocouple myself?

It’s easy to replace and a new one costs $5 to $10. Rather than trying to unfasten the thermocouple inside the water heater’s burning chamber, it’s easier to remove the whole burner and thermocouple assembly.

How long does a thermocouple last?

Thermocouples are rigorously tested and should last for years. Indeed, experts believe a four-year check cycle is all that is needed to make sure things are functioning properly.

Begin typing your search term above and press enter to search. Press ESC to cancel.